    Type: Online Output Power Factor: 0.8
    Phase: Three Phase Protection: Over Load/Current/Voltage, Short Circuit Etc
    Display: Digital LCD Display H.S. Code: 8504402000

     

     External Battery Bank Double Conversion Online UPS  Long Backup Time

     

    Application

    Industrial equipment, Financial and Securities, Large Data rooms, Medical and Health

     

    Key Features

    • Online double-conversion

    • True galvanic isolation transformer design      

    • DSP technology guarantees high reliability                      
    • Control designed to withstand all kinds of loads    

    • Accept dual-mains input  from Utility Power and Generator both

    • Parallel operation with up to 4 units (option)   

    • Uninterruptible Power Supply with long backup time and pure sine wave output                                                 

    • Intelligent battery management to prolong battery lifecycle                                
    • Redundant fan design and independent ventilation enhance durable operation under

      harsh environment                                
    • Adjustable battery numbers                                                        
    • Variety of communication options available    

    • Good Quality, Stable Performance and CE Certificate

    • Warranty: 3 Years                            

     

     

    Technical Specification

     3P/3P ONLINE UPS SELECTION GUIDE
      LS33 Series 10K - 80Kva
    MODEL 10K 20K 30K  40K 60K 80K
    CAPACITY 10KVA/        8KW 20KVA/ 16KW

    30KVA/ 24KW

    40KVA/ 32KW 60KVA/ 48KW 80KVA/ 64KW
    INPUT
    Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
    Acceptable Voltage Range 305VAC ~ 460VAC
    Frequency 46-54Hz or 56-64Hz
    INVERTER
    Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
    Precision Stationary: ±1%
     Transitory: ±5% (load variations 100-0-100%)
    Frequency 50/60 Hz synchronised ±1 %
    With mains absent ±0.1 Hz
    Max. Synchronisation Speed ±1 Hz/s
    Waveform Pure Sinewave
    Total Harmonic Distortion (THDv) <2% (Linear Load)
    <5% (Non-linear Load)
    Phase Displacement 120º ±1% (balanced load)
    120º ±2% (imbalances 50% of the load)
    Dynamic Recovery Time 1 cycle at 98 % of the static value
    Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
    Admissible Crest Factor 3:1
    Admissible Power Factor 0.6~1 (inductive or capacitive)
    Imbalance Output Voltage @ 100% Unbalanced Load <1%
    Current Limit High overload, short-circuit: RMS Voltage Limit
     High Crest-Factor current: Peak Voltage Limit
    STATIC BYPASS
    Type Solid state
    Voltage 3 x 380VAC/400VAC (3Ph + N)
    Frequency 50/60 Hz
    Activation Criterion Microprocessor control
    Transfer Time Zero
    Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
    Transfer to Bypass Immediate, for overloads above 160%
    Retransfer Automatic after alarm clear
    MAINTENANCE BYPASS
    Type Without interruption
    Voltage 3 x 400V (3Ph + N)
    Frequency 50/60 Hz
    Overall Efficiency Line Mode 90% 91% 92% 93%
    Battery Mode 90% 91% 93% 93%
    BATTERY & CHARGER
    Battery Type and Numbers 12VDC x 16 pcs 12VDC x 32 pcs (29~32 pcs adjustable)
    Nominal Battery Voltage 192 VDC 384 VDC (Based on 32pcs batteries)
    Charging Method CC/CV
    Precision  ±1%
    Charging Current Max.: 40 A
    Charging Voltage 216 VDC 432 VDC (Based on 32pcs batteries)
    PHYSICAL
    Dimensions, D x W x H(mm) 656 x 405 x 817 656 x 405 x 941 840 x 432 x 1140 975 x 554 x 1286
    Net Weight (Kgs) 180 205 295 330 451 519